Sign In | Join Free | My burrillandco.com
Home > UL Version Emergency LED Driver >

Optional Infrared Remote Control AC Solution Emergency Converter For LED Luminaire

Shenzhen HAISEN Technology Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Optional Infrared Remote Control AC Solution Emergency Converter For LED Luminaire from wholesalers
     
    Buy cheap Optional Infrared Remote Control AC Solution Emergency Converter For LED Luminaire from wholesalers
    • Buy cheap Optional Infrared Remote Control AC Solution Emergency Converter For LED Luminaire from wholesalers
    • Buy cheap Optional Infrared Remote Control AC Solution Emergency Converter For LED Luminaire from wholesalers

    Optional Infrared Remote Control AC Solution Emergency Converter For LED Luminaire

    Ask Lasest Price
    Brand Name : HAISEN
    Model Number : ES-EIA-01S SERIES
    Certification : UL BC
    Price : Negotiable
    Payment Terms : D/A, D/P, T/T
    Supply Ability : 1-10pcs Samples Within 2-3 Days; Bulk Order Within 28 Days
    Delivery Time : Standard Models Within 3 Weeks
    • Product Details
    • Company Profile

    Optional Infrared Remote Control AC Solution Emergency Converter For LED Luminaire

    AC Solution Emergency Battery Backup For LED Luminaire With Optional Infrared Remote Control

    Description

    • AC solution EM for 9-350W LED luminaire.
    • It must connect 0/1-10V dimming wires if power of luminaire>power of EM.

    Features

    • UL listed for field or factory installation, CEC title 20 compliant
    • Compliance with American NFPA 101 life Safety Code
    • Constant output power
    • 2-in-1 LED test switch and indicator light included
    • Manual testing via remote control(optional)
    • Monthly/annual self-testing
    • With multi-protection function:

    ​ -Battery overcharge protection
    -Battery over-discharge protection
    -Output overload protection
    -Short-circuit protection

    -Open load protection

    • 5 years limited warranty


    ELECTRICAL SPECIFICATIONS

    Input voltage100-347 VAC 50/60Hz
    Input Current0.1A max
    Input Power8W Max
    Power Factor0.6@100VAC,0.5@347VAC
    Input of LED loadAC 6A Max
    Output Voltage140Vdc
    BatteryLithium
    Recharge duration<24Hrs
    Emergency duration90mins
    Ambient temp0-50°C(32℉-122℉)

    MODEL SELECTION TABLE

    Models

    ES-EIA09-01S

    ES-EIA15-01S

    ES-EIA25-01SES-EIA25-01SES-EIA25-01S
    Emergency wattage

    9W



    15W


    25W32W38W

    Battery capacity

    14.8V/1800mAh
    14.8V/600mAh
    14.8V/4400mAh
    14.8V/5200mAh
    14.8V/6600mAh
    Compatible led fixture
    9-80W LED lamp with
    0-10V dimming or
    LED lamp less than 9W
    without 0-10V dimming
    15-120W LED lamp with
    0-10V dimming or
    LED lamp less than 15W
    without 0-10V dimming
    25-200W LED lamp with
    0-10V dimming or
    LED lamp less than 25W
    without 0-10V dimming
    32-300W LED lamp with
    0-10V dimming or
    LED lamp less than 32W
    without 0-10V dimming
    38-350W LED lamp with
    0-10V dimming or
    LED lamp less than 38W
    without 0-10V dimming

    DIMENSION

    ModelL

    W


    H

    ES-EIA09-01S

    14.6"(371mm)
    1.62"(41.4mm)
    1.43"(36.4mm)

    ES-EIA15-01S

    14.6"(371mm)
    1.62"(41.4mm)
    1.43"(36.4mm)

    Optional Infrared Remote Control AC Solution Emergency Converter For LED Luminaire

    Model

    L


    WH

    ES-EIA25-01S

    2.24"(311mm)
    2.59"(66mm)
    1.53"(39mm)

    ES-EIA32-01S

    12.24"(311mm)
    2.59"(66mm)
    1.53"(39mm)

    ES-EIA38-01S

    12.24"(311mm)
    2.59"(66mm)
    1.53"(39mm)

    Optional Infrared Remote Control AC Solution Emergency Converter For LED Luminaire

    NORMAL MODE
    Fixtures will operate normally when power is available. When an outage occurs, the fixture will switch to emergency mode, delivering power to the fixture for up to 90 minutes.

    EMERGENCY MODE

    1.The emergency battery backup enters the emergency mode immediately after the mains power failure.

    2.Stop the emergency and return to the charging state after the mains power call.


    SELF-TEST

    MONTHLY SELF-TEST
    It will automatically perform a monthly self-test every 30 days with a duration of 30S to check whether the emergency function is normal, and automatically restore to normal charging after 30S discharged.
    ANNUAL SELF-TEST
    An annual self-test will be done every year(12 months) with a duration of more than 180mins to check whether the capacity of the battery pack is normal, and automatically restore to normal charging after fully discharged. (the condition of annual test is that the battery pack is fully charged). If the annual inspection is interrupted, it will be retested after recovery and when the test conditions are met. (Possibility of interruption: such as sudden power failure, sudden manual test).

    Optional Infrared Remote Control AC Solution Emergency Converter For LED Luminaire


    ES-EIA-01S.pdf


    Quality Optional Infrared Remote Control AC Solution Emergency Converter For LED Luminaire for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen HAISEN Technology Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)